Standard test sieve, laboratory test sieve, 200mm test sieve
Sieving is an effective method for particle size measurement. It is commonly used for Quality Control in almost all industries such as chemicals, mining and metallurgy, food, cosmetics, pharmaceuticals and any laboratory involved in particle size analysis. The displayed test sieve is a good helper for particle size analysis.
Features of test sieve
1. Typically requires 50-150g of sample material
2. Setting time limits for 1 second -9999 seconds
3. Up to 9 fractions in one sieving operation
4. One person can pick up it
5. Approved ISO 9001:2008, CE and BV certificates
6. Accurate mesh size guarantees precise analysis of sample
Please read the following information before usage of test sieve:
How to operate for getting good analysis result?
If you need one set of test sieve, please let's know the following requirements:
1. How many sieves you need at once
2. The mesh size of each sieves
3. Please suggest the voltage in your plant
Email us and get the best quotation.
Sieving is an effective method for particle size measurement. It is commonly used for Quality Control in almost all industries such as chemicals, mining and metallurgy, food, cosmetics, pharmaceuticals and any laboratory involved in particle size analysis. The displayed test sieve is a good helper for particle size analysis.
Features of test sieve
1. Typically requires 50-150g of sample material
2. Setting time limits for 1 second -9999 seconds
3. Up to 9 fractions in one sieving operation
4. One person can pick up it
5. Approved ISO 9001:2008, CE and BV certificates
6. Accurate mesh size guarantees precise analysis of sample
Please read the following information before usage of test sieve:
Before using |
a. Prior to operate the sieve shaker, ensure all the components are fastened, no broken on the sieves, no damage on the machine body, and the electrical cables are connected properly. b. Please check whether the machine model and specification are the same as your order. c. Power supply is the same as shown on the machine plaque. (Tolerance for voltage is +/- 10%) |
Be using |
a. Make sure the machine has been positioned horizontally b. Check the power and make sure it is in line with the required, check grounding wire. c. The machine body cannot contact with other things. d. Must use the fixing nut to fix the sieves. |
After using |
a. Turn off the power b. Clean the sieves after operation, place the machine in the right place |
How to operate for getting good analysis result?
Step 1 | Weighing the tested material |
Step 2 | Place sieves with required mesh on the machine base sequentially |
Step 3 | Pour the tested material into the top of sieve |
Step 4 | The above step is OK, then cover with the lid and set the right time |
Step 5 | Power on |
Step 6 | It's time to set up, power off |
Step 7 | Remove the lid and sieves one by one from the top to bottom |
Step 8 | Summary: measure the weight of test material leaved on each sieve and bottom pan, and then gets their proportion and other related analysis result. |
If you need one set of test sieve, please let's know the following requirements:
1. How many sieves you need at once
2. The mesh size of each sieves
3. Please suggest the voltage in your plant
Email us and get the best quotation.